Data Center Modular provides pre-engineered and pre-fabricated Cooling and Mechanical Modules, offering a controlled and efficient solution for critical data center infrastructure. These modules integrate essential cooling, power distribution, and mechanical systems into a single, deployable unit, accelerating project timelines and ensuring consistent quality.

  • Modular Buildings
  • Power Modules
  • Cooling Modules

Cooling and Mechanical Modules from Data Center Modular represent a critical advancement in data center infrastructure deployment, offering a streamlined approach to integrating complex environmental control and utility systems. These modules are meticulously engineered and fabricated off-site, encompassing everything from CRAC/CRAH units, chillers, pumps, and heat exchangers to associated piping, electrical distribution, and control systems. The off-site construction methodology significantly reduces on-site labor requirements, minimizes construction waste, and allows for parallel development tracks – module fabrication coinciding with site preparation. This approach is particularly valuable for projects requiring rapid deployment, expansion of existing facilities, or establishment of new data centers in diverse geographical locations, providing a predictable and high-quality solution.

Our Cooling and Mechanical Modules are designed with flexibility in mind, accommodating a wide range of thermal management strategies and mechanical system requirements. Typical configurations include direct expansion (DX) cooling, chilled water systems, evaporative cooling, and hybrid approaches, all integrated within a robust, weatherproof enclosure. These modules can be configured to support various IT load densities and environmental specifications, ensuring optimal operating conditions for sensitive equipment. Integration considerations extend to seamless connection points for site utilities, including primary power feeds, water supply and return lines, and network communication for building management systems. The modular design facilitates future scalability, allowing for phased expansion by simply adding more modules as demand grows, without disrupting existing operations.

The technical specifications and integration requirements for Cooling and Mechanical Modules are thoroughly addressed during the design and fabrication phases. Data Center Modular collaborates with project teams to define precise equipment layouts, airflow patterns, acoustic considerations, and structural load requirements. We focus on delivering a module that is ready for final site integration, with all internal systems pre-commissioned where feasible. This includes factory acceptance testing (FAT) to verify system functionality and performance before shipment. While Data Center Modular focuses on the module's internal integrity and functionality, successful deployment hinges on careful planning for site-specific elements such as foundation design, utility trenching, and crane access for module placement. Our process is geared towards providing a high-quality, factory-built solution that simplifies the on-site execution phase for the general contractor and engineering team.

Technician insight

In Ashburn, the thing that catches most project teams out with Cooling and Mechanical Modules is often the need for robust structural considerations for the module's foundation, particularly given the variable soil conditions and potential for expansive clay. Undersized or inadequately designed foundations can lead to differential settlement over time, impacting the integrity of the module and its connections to site utilities.

Cooling and Mechanical Modules Services We Offer

Chilled Water Cooling Modules

Pre-fabricated modules integrating chillers, pumps, piping, and controls for high-density cooling applications, providing efficient heat rejection for large-scale data centers.

Direct Expansion (DX) Cooling Modules

Self-contained cooling units utilizing refrigerant-based systems, ideal for smaller deployments or targeted cooling zones where chilled water infrastructure is not present.

Evaporative Cooling Modules

Modules designed for energy-efficient cooling in suitable climates, leveraging the principles of evaporative heat transfer to reduce power consumption for thermal management.

Hybrid Cooling Modules

Integrated solutions combining multiple cooling technologies, such as DX with evaporative assist, to optimize energy efficiency and performance across varying ambient conditions.

Mechanical Plant Modules

Comprehensive modules housing all essential mechanical infrastructure, including pumps, heat exchangers, filtration systems, and associated controls, serving as a centralized utility hub.

Power Distribution Modules with Cooling

Combined modules integrating electrical switchgear, transformers, and PDUs alongside cooling units, streamlining power and thermal management into a single deployable asset.

How it works

  1. 1

    Initial Consultation & Requirements Definition

    We engage with your project team to understand the specific cooling loads, environmental conditions, electrical requirements, and desired operational parameters. This phase involves detailed discussions to define the scope and technical specifications for your Cooling and Mechanical Modules.

  2. 2

    Conceptual Design & Engineering Review

    Based on the defined requirements, our engineering team develops conceptual designs, including equipment layouts, system schematics, and preliminary structural considerations. We collaborate closely with your engineers to ensure alignment with overall project architecture and performance objectives.

  3. 3

    Detailed Design & Fabrication Planning

    Upon design approval, we proceed with detailed engineering, generating comprehensive fabrication drawings and material specifications. This stage includes procurement of long-lead items and meticulous planning for the off-site construction process to optimize efficiency and quality.

  4. 4

    Module Fabrication & Assembly

    In our controlled manufacturing environment, the Cooling and Mechanical Modules are constructed, integrating all specified equipment, piping, electrical systems, and controls. Rigorous quality checks are performed at each stage of assembly to ensure adherence to design and industry standards.

  5. 5

    Factory Acceptance Testing (FAT)

    Before shipment, each module undergoes comprehensive Factory Acceptance Testing. This involves powering up systems, verifying control logic, and testing operational parameters to ensure all components function as designed and meet performance specifications, often with client representatives present.

  6. 6

    Logistics & Delivery Coordination

    Once FAT is complete and approved, we coordinate all necessary logistics for transportation. This includes securing specialized carriers and planning the delivery route to ensure the safe and timely arrival of the pre-fabricated Cooling and Mechanical Modules to your designated site.

Pricing

Pricing for Cooling and Mechanical Modules is highly customized and depends on several key factors. These include the module's dimensions and structural design, the specific cooling equipment and mechanical systems integrated, electrical load requirements, and any specialized finishes. The quantity of modules ordered, the final destination, logistical complexities, and the project schedule also significantly influence the overall cost.

Data Center Modular — modular data center infrastructure in Ashburn

Good to know

Cooling and Mechanical Modules — FAQs

Still have questions? We're happy to talk it through.

+ What are the typical lead times for Cooling and Mechanical Modules?
Lead times for Cooling and Mechanical Modules vary significantly based on the complexity of the design, the availability of specific components, and our current production schedule. We recommend engaging early in your project planning to discuss your specific timeline, allowing us to provide a more accurate estimate.
+ Can your modules be customized for specific environmental conditions?
Yes, our Cooling and Mechanical Modules are designed with a high degree of customization. We can engineer solutions to accommodate a wide range of ambient temperatures, humidity levels, and seismic requirements, ensuring optimal performance in diverse geographical and operational environments.
+ How do your modules integrate with existing data center infrastructure?
Our modules are designed for seamless integration. We provide clearly defined connection points for site utilities such as power, water, and data. Our engineering team collaborates with your project's engineers to ensure compatibility with your existing building management systems (BMS) and overall site infrastructure.
+ What level of commissioning is performed before modules leave your facility?
We conduct comprehensive Factory Acceptance Testing (FAT) on all Cooling and Mechanical Modules. This includes powering up systems, verifying control logic, testing operational sequences, and ensuring all components function according to design specifications. This reduces on-site commissioning efforts.
+ What are the structural requirements for deploying these modules?
Deployment requires a prepared, level foundation capable of supporting the module's weight and any dynamic loads. Specific structural requirements will be detailed in the engineering drawings provided, and these must be integrated into your site's foundation design and preparation plans.
+ Are your modules suitable for outdoor deployment?
Yes, our Cooling and Mechanical Modules are designed for outdoor deployment. They feature robust, weatherproof enclosures and are constructed with materials and finishes suitable for long-term exposure to various environmental conditions, protecting the internal critical infrastructure.

Planning a Modular Data Center Project?